{"id":2559,"date":"2019-12-13T14:44:37","date_gmt":"2019-12-13T13:44:37","guid":{"rendered":"http:\/\/www.aep.it\/prodotto\/uncategorized\/star-f\/"},"modified":"2025-10-31T15:37:33","modified_gmt":"2025-10-31T14:37:33","slug":"star-f","status":"publish","type":"product","link":"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/","title":{"rendered":"STAR-F"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]<\/p>\n<p>Internally the microcontroller process the signals coming from the sensors through a 24 bit (\u00b150.000 divisions at 2mV\/V) analogue digital converter at a conversion frequency varying from 5Hz at 4800Hz by making it suitable for every application that may require both high resolution and high sampling frequencies. The display of measurements happens through a big graphic backlighted display. Star is equipped with USB interface that allows both the communication in real-time with a PC and the recharge of the internal long-lasting and great reliability battery (Li-Ion). In addition to the direct reading of the measurements, it is possible to detect PEAKS, block the measurement on the display thanks to the HOLD function and through the internal DATA LOGGER it is possible to record up to 130.000 measurement at programmed intervals or manually through the REC button. On request, as an\u00a0<strong>OPTION<\/strong>\u00a0it is possible to integrate a WIRELESS interface that allows to communicate with PC, TABLET or PLC in real time. By using WinWIMOD software it is possible to create a NETWORK with a max. number of 32 units, the net can consist of both STAR instruments and sensors interfaced with WIMOD. Metal case Li-Ion internal battery which ensures a 24 hours AUTONOMY Protection class IP40 Functions ZERO, FILTER, PEAK, AUTO POWER OFF, DATA LOGGER, REC &#8230;.. USB output Included: travelling case made of ABS and feeder with USB cable<\/p>\n<p>[\/vc_column_text][vc_separator][vc_column_text]<\/p>\n<p><strong>ACCESSORIES<\/strong><\/p>\n<p>[\/vc_column_text][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;2545&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<p>Accessory Kit for tensile and compression test of materials<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;2548&#8243; img_size=&#8221;full&#8221; onclick=&#8221;link_image&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<p><strong>Travelling case<\/strong> <strong>feeder with USB cable <\/strong><\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;2551&#8243; img_size=&#8221;full&#8221; onclick=&#8221;link_image&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<p align=\"justify\"><strong>Quik Analyzer Light:<\/strong> Software for monitoring analyzing and recording the run of tests which can involve up to 1 instrument.<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Professional ergonomic indicator extremely versatile and easy to be used for measurement of FORCE, WEIGHT, PRESSURE (gas), VACUUM, TORQUE and DISPLACEMENT. It is possible to\u00a0<strong>integrate inside<\/strong>\u00a0a\u00a0<strong>FORCE<\/strong>\u00a0sensor from\u00a0<strong>10 N<\/strong>\u00a0to\u00a0<strong>5 kN<\/strong>\u00a0or a pressure sensor (relative, absolute or differential up to max. 5bar) while from the external input it is possible to connect strain gauges sensors with output in mV\/V such as: load cells, force transducers, pressure transducers, torque and displacement transducers. AUTOMATIC recognition of FORCE, WEIGHT, VACUUM, PRESSURE, TORQUE and DISPLACEMENT external transducers (max. 7) LCD graph DISPLAY with 3 levels of backlighting to adapt itself to any conditions of external brightness and with the possibility of rotating the \u00a0visualization of 180\u00b0. DIGITAL CALIBRATIONS protected by Password with full scale programming or with the \u201cLINEARIZATION by points\u201d of transducers, for every transducer it is possible to separately calibrate both the positive and the negative field. (Example: Tension and Compression) DATALOGGER allows to memorize measurements and to keep them in the internal memory even in case of instrument switching off. (max. 130.000 recordings)<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-8975\" src=\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/label-eac-2.jpg\" alt=\"\" width=\"150\" height=\"70\" \/><\/p>\n","protected":false},"featured_media":7777,"template":"","meta":[],"product_brand":[],"product_cat":[93],"product_tag":[],"class_list":{"0":"post-2559","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-force-transducers","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple","12":"berocket_lgv_grid","13":"berocket_lgv_list_grid"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>STAR-F | AEP transducers<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"STAR-F | AEP transducers\" \/>\n<meta property=\"og:description\" content=\"Professional ergonomic indicator extremely versatile and easy to be used for measurement of FORCE, WEIGHT, PRESSURE (gas), VACUUM, TORQUE and DISPLACEMENT. It is possible to\u00a0integrate inside\u00a0a\u00a0FORCE\u00a0sensor from\u00a010 N\u00a0to\u00a05 kN\u00a0or a pressure sensor (relative, absolute or differential up to max. 5bar) while from the external input it is possible to connect strain gauges sensors with output in mV\/V such as: load cells, force transducers, pressure transducers, torque and displacement transducers. AUTOMATIC recognition of FORCE, WEIGHT, VACUUM, PRESSURE, TORQUE and DISPLACEMENT external transducers (max. 7) LCD graph DISPLAY with 3 levels of backlighting to adapt itself to any conditions of external brightness and with the possibility of rotating the \u00a0visualization of 180\u00b0. DIGITAL CALIBRATIONS protected by Password with full scale programming or with the \u201cLINEARIZATION by points\u201d of transducers, for every transducer it is possible to separately calibrate both the positive and the negative field. (Example: Tension and Compression) DATALOGGER allows to memorize measurements and to keep them in the internal memory even in case of instrument switching off. (max. 130.000 recordings)\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/\" \/>\n<meta property=\"og:site_name\" content=\"AEP transducers\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/AEP-transducers-212611005540305\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-31T14:37:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/STAR-F.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/\",\"url\":\"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/\",\"name\":\"STAR-F | AEP transducers\",\"isPartOf\":{\"@id\":\"https:\/\/www.aep.it\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/STAR-F.jpg\",\"datePublished\":\"2019-12-13T13:44:37+00:00\",\"dateModified\":\"2025-10-31T14:37:33+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/#primaryimage\",\"url\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/STAR-F.jpg\",\"contentUrl\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/STAR-F.jpg\",\"width\":600,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.aep.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.aep.it\/en\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"STAR-F\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.aep.it\/en\/#website\",\"url\":\"https:\/\/www.aep.it\/en\/\",\"name\":\"AEP transducers\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.aep.it\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.aep.it\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.aep.it\/en\/#organization\",\"name\":\"AEP Transducers\",\"url\":\"https:\/\/www.aep.it\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png\",\"contentUrl\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png\",\"width\":2000,\"height\":284,\"caption\":\"AEP Transducers\"},\"image\":{\"@id\":\"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/AEP-transducers-212611005540305\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"STAR-F | AEP transducers","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/","og_locale":"en_US","og_type":"article","og_title":"STAR-F | AEP transducers","og_description":"Professional ergonomic indicator extremely versatile and easy to be used for measurement of FORCE, WEIGHT, PRESSURE (gas), VACUUM, TORQUE and DISPLACEMENT. It is possible to\u00a0integrate inside\u00a0a\u00a0FORCE\u00a0sensor from\u00a010 N\u00a0to\u00a05 kN\u00a0or a pressure sensor (relative, absolute or differential up to max. 5bar) while from the external input it is possible to connect strain gauges sensors with output in mV\/V such as: load cells, force transducers, pressure transducers, torque and displacement transducers. AUTOMATIC recognition of FORCE, WEIGHT, VACUUM, PRESSURE, TORQUE and DISPLACEMENT external transducers (max. 7) LCD graph DISPLAY with 3 levels of backlighting to adapt itself to any conditions of external brightness and with the possibility of rotating the \u00a0visualization of 180\u00b0. DIGITAL CALIBRATIONS protected by Password with full scale programming or with the \u201cLINEARIZATION by points\u201d of transducers, for every transducer it is possible to separately calibrate both the positive and the negative field. (Example: Tension and Compression) DATALOGGER allows to memorize measurements and to keep them in the internal memory even in case of instrument switching off. (max. 130.000 recordings)","og_url":"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/","og_site_name":"AEP transducers","article_publisher":"https:\/\/www.facebook.com\/AEP-transducers-212611005540305","article_modified_time":"2025-10-31T14:37:33+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/STAR-F.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/","url":"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/","name":"STAR-F | AEP transducers","isPartOf":{"@id":"https:\/\/www.aep.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/#primaryimage"},"image":{"@id":"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/#primaryimage"},"thumbnailUrl":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/STAR-F.jpg","datePublished":"2019-12-13T13:44:37+00:00","dateModified":"2025-10-31T14:37:33+00:00","breadcrumb":{"@id":"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/#primaryimage","url":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/STAR-F.jpg","contentUrl":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/STAR-F.jpg","width":600,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/www.aep.it\/en\/product\/force-transducers\/star-f\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aep.it\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.aep.it\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"STAR-F"}]},{"@type":"WebSite","@id":"https:\/\/www.aep.it\/en\/#website","url":"https:\/\/www.aep.it\/en\/","name":"AEP transducers","description":"","publisher":{"@id":"https:\/\/www.aep.it\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aep.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.aep.it\/en\/#organization","name":"AEP Transducers","url":"https:\/\/www.aep.it\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png","contentUrl":"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png","width":2000,"height":284,"caption":"AEP Transducers"},"image":{"@id":"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/AEP-transducers-212611005540305"]}]}},"_links":{"self":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product\/2559","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/media\/7777"}],"wp:attachment":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/media?parent=2559"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product_brand?post=2559"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product_cat?post=2559"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product_tag?post=2559"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}