{"id":3490,"date":"2019-12-20T09:14:54","date_gmt":"2019-12-20T08:14:54","guid":{"rendered":"http:\/\/www.aep.it\/prodotto\/uncategorized\/mp2plus\/"},"modified":"2025-11-03T15:42:20","modified_gmt":"2025-11-03T14:42:20","slug":"mp2plus","status":"publish","type":"product","link":"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/","title":{"rendered":"MP2PLUS"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]DIN43700 case.<\/p>\n<div>Other features and functions of importance are:<br \/>\nGraphical, large and high resolution LCD display with backlit.<br \/>\nAutomatic UNIT CONVERSIONS in many specific units for each type of transducers.<br \/>\nFunction MULTIMETER which displays the signal of the sensor directly in mV\/V, V or mA.<br \/>\nUser selectable language : ITALIAN or ENGLISH.<br \/>\nFunction ZERO and AUTOZERO to reset automatically the measure if the measurement is below a set threshold.<br \/>\nFunction\u00a0<strong>COUNTING<\/strong>\u00a0to define the number of pieces on the scale.<br \/>\nFunction of HOLD, PEAK, programmable FILTER.<br \/>\nFunction of DISCHARGE in order to measure the amount of product discharged for example from a tank.<br \/>\nFunction TOTAL to perform the sum of channels CH1 and CH2.<br \/>\nFunction KEY LOCK to protect the instrument settings by unauthorized persons.<br \/>\nFunction CLOCK-CALENDAR (Option) with date and time.<br \/>\n24 columns PRINTER (option) connected to the serial port through which it is possible to print the measuring points with the date and time and the data of the company that carried out the survey.<br \/>\nREPEATER Function: The instrument can be configured to display (in the form passive as Slave) measures from the RS232 serial port (for example from another MP2Plus &#8211; Master) to a remote view of the measures.<br \/>\nIn this case all the features enabled on the MP2Plus Slave will be active (Setpoint, USB, printer, logger etc). The REPEATER function is active for one channel.<\/div>\n<div>The instrument can have one or two independent channels.<br \/>\nFor each input channel, you can calibrate the signal coming from the sensor both in the POSITIVE RANGE and in the NEGATIVE RANGE (Example in tension and compression) through 3 different modes:<br \/>\nCalibration with Full Scale: characterization through the programming of the transducer full scale and sensitivity in both the positive and negative range.<br \/>\nCalibration for POINTS: linearity correction by programming 5 known points in both the positive and negative range.<br \/>\nKnown Weight: practice characterization (in the field) by imposing a known weight, pressure, torque to the sensor and calibrating the transducer output to this reference value.<\/div>\n<div>As\u00a0<strong>OPTIONS<\/strong>\u00a0the instrument can be equipped with:<\/div>\n<p>Additional input channel CH2 with a synchronization system that allows to acquire at the same instant the measurement of CH1 and CH2 channels.<br \/>\nOne or two Analog Outputs programmable as voltage (\u00b1 10V, 0\/5V, 0\/10V, \u00b15V) or current (4-20mA, 0-20mA, 0-24mA) that can be associated to different channels or to the TOTAL (sum of two channels).<br \/>\nA serial RS232 line to directly connect the device to a PC, PLC or a serial PRINTER. Moreover MP2Plus can be programmed to work as REPEATER.<br \/>\nA serial RS485 line with protocol MODBUS RTU normally used to connect multiple instruments in a same network to a PLC.<br \/>\nWIRELESS transmission designed to transmit measurements to other devices by radio at a distance up to 100m.<br \/>\nA powerful DATALOGGER with non-volatile memory, which allows to store data at the maximum acquisition speed, synchronize recordings with an internal clock-calendar and eventually export data to a file using an USB stick in .csv file format that can be transferred directly to Microsoft Excel.<br \/>\n[\/vc_column_text][vc_separator][vc_column_text]<strong>ACCESSORIES<\/strong>[\/vc_column_text][vc_row_inner content_placement=&#8221;middle&#8221;][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;3479&#8243; img_size=&#8221;full&#8221; onclick=&#8221;link_image&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<p align=\"justify\"><strong>MPsupervisor<br \/>\n<\/strong><\/p>\n<p>A dedicated program that allows an immediate interfacing through the USB port with the MP2Plus and allows you to view graphs, export data to Microsoft Excel directly from the PC and set all configuration parameters.<br \/>\nThe program also allows you to download a Data Logger carried out using the internal memory or the USB Flash Memory and display the respective curves of acquisition.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner content_placement=&#8221;middle&#8221;][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;3461&#8243; img_size=&#8221;full&#8221; onclick=&#8221;link_image&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]Serial cable RS232<\/p>\n<p>USB cable[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner content_placement=&#8221;middle&#8221;][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;7716&#8243; img_size=&#8221;full&#8221; onclick=&#8221;link_image&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<b>MP2PLUS<\/b> couple[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner content_placement=&#8221;middle&#8221;][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;7704&#8243; img_size=&#8221;full&#8221; onclick=&#8221;link_image&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<b>MP2PLUS<\/b> field bus[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner content_placement=&#8221;middle&#8221;][vc_column_inner width=&#8221;1\/2&#8243;][vc_images_carousel images=&#8221;7710,7713&#8243; img_size=&#8221;full&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text]<b>MP2PLUS<\/b> with 1 and 2 tank[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>NEW PERFORMANCES <\/strong> <strong>&#8220;THE EVOLUTION OF THE SPECIES&#8221;<\/strong>\u00a0: after more than 30 years of service in the various versions the new\u00a0<strong>MP2<\/strong><em>Plus<\/em>\u00a0is born. <strong>MP2<\/strong><em>Plus<\/em>\u00a0is a Professional Digital Indicator with\u00a0<strong>1\u00a0<\/strong>(standard)or<strong>\u00a02\u00a0<\/strong>(option)<strong>\u00a0inputs<\/strong>, suitable for receiving signals from strain gauge sensors, transmitters with voltage or current output, PT100, potentiometer, ENCODER and LVDT. Particularly suitable for both static and dynamic applications, for calibration and verification in metrology laboratories or industrial environments where it is necessary to make measurements of\u00a0<strong>WEIGHT, FORCE, PRESSURE, TORQUE, DISPLACEMENTS, ANGLE, SPEED\u00a0<\/strong>and<strong>\u00a0TEMPERATURE. <\/strong>To\u00a0<strong>FIT EVERY APPLICATION<\/strong>\u00a0the instrument can be configured and customized:\u00a0 the function keys F1, F2, F3 and F4 can be programmed for the function of interest such as: PEAK, HOLD, RELEASE, TX DATA DATALOG, DISCHARGE, ZOOM. Each input channels can be supplied in\u00a0<strong>7<\/strong>\u00a0different configurations:<\/p>\n<ul>\n<li>\u00b12mV\/V,\u00a0\u00b13mV\/V<\/li>\n<li>4-20mA, 0-20mA<\/li>\n<li>\u00b110V,\u00a0\u00b15V<\/li>\n<li>PT100<\/li>\n<li>ENCODER<\/li>\n<li>POTENTIOMETER<\/li>\n<li><strong>LVDT<\/strong><\/li>\n<\/ul>\n<p>On request\u00a0<strong>FIELDBUS<\/strong>\u00a0communication selectable among :\u00a0<strong>DeviceNet<\/strong>,<strong>\u00a0CANopen<\/strong>,<strong>\u00a0EtherNet\/IP, PROFIBUS<\/strong>,<strong>\u00a0PROFINET<\/strong>\u00a0to be connected inside a standard PLC network. <span id=\"result_box\" class=\"short_text\" lang=\"en\">NEW\u00a0<strong>COUNTING\u00a0<\/strong><span class=\"alt-edited\">function<\/span><\/span><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-8975\" src=\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/label-eac-2.jpg\" alt=\"\" width=\"150\" height=\"70\" \/><\/p>\n","protected":false},"featured_media":3482,"template":"","meta":[],"product_brand":[],"product_cat":[89],"product_tag":[],"class_list":{"0":"post-3490","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-instruments","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple","12":"berocket_lgv_grid","13":"berocket_lgv_list_grid"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>MP2PLUS | AEP transducers<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MP2PLUS | AEP transducers\" \/>\n<meta property=\"og:description\" content=\"NEW PERFORMANCES &quot;THE EVOLUTION OF THE SPECIES&quot;\u00a0: after more than 30 years of service in the various versions the new\u00a0MP2Plus\u00a0is born. MP2Plus\u00a0is a Professional Digital Indicator with\u00a01\u00a0(standard)or\u00a02\u00a0(option)\u00a0inputs, suitable for receiving signals from strain gauge sensors, transmitters with voltage or current output, PT100, potentiometer, ENCODER and LVDT. Particularly suitable for both static and dynamic applications, for calibration and verification in metrology laboratories or industrial environments where it is necessary to make measurements of\u00a0WEIGHT, FORCE, PRESSURE, TORQUE, DISPLACEMENTS, ANGLE, SPEED\u00a0and\u00a0TEMPERATURE. To\u00a0FIT EVERY APPLICATION\u00a0the instrument can be configured and customized:\u00a0 the function keys F1, F2, F3 and F4 can be programmed for the function of interest such as: PEAK, HOLD, RELEASE, TX DATA DATALOG, DISCHARGE, ZOOM. Each input channels can be supplied in\u00a07\u00a0different configurations:   \u00b12mV\/V,\u00a0\u00b13mV\/V  4-20mA, 0-20mA  \u00b110V,\u00a0\u00b15V  PT100  ENCODER  POTENTIOMETER  LVDT  On request\u00a0FIELDBUS\u00a0communication selectable among :\u00a0DeviceNet,\u00a0CANopen,\u00a0EtherNet\/IP, PROFIBUS,\u00a0PROFINET\u00a0to be connected inside a standard PLC network. NEW\u00a0COUNTING\u00a0function\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/\" \/>\n<meta property=\"og:site_name\" content=\"AEP transducers\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/AEP-transducers-212611005540305\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-03T14:42:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-mp2plus.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/\",\"url\":\"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/\",\"name\":\"MP2PLUS | AEP transducers\",\"isPartOf\":{\"@id\":\"https:\/\/www.aep.it\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-mp2plus.jpg\",\"datePublished\":\"2019-12-20T08:14:54+00:00\",\"dateModified\":\"2025-11-03T14:42:20+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/#primaryimage\",\"url\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-mp2plus.jpg\",\"contentUrl\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-mp2plus.jpg\",\"width\":600,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.aep.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.aep.it\/en\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"MP2PLUS\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.aep.it\/en\/#website\",\"url\":\"https:\/\/www.aep.it\/en\/\",\"name\":\"AEP transducers\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.aep.it\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.aep.it\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.aep.it\/en\/#organization\",\"name\":\"AEP Transducers\",\"url\":\"https:\/\/www.aep.it\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png\",\"contentUrl\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png\",\"width\":2000,\"height\":284,\"caption\":\"AEP Transducers\"},\"image\":{\"@id\":\"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/AEP-transducers-212611005540305\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"MP2PLUS | AEP transducers","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/","og_locale":"en_US","og_type":"article","og_title":"MP2PLUS | AEP transducers","og_description":"NEW PERFORMANCES \"THE EVOLUTION OF THE SPECIES\"\u00a0: after more than 30 years of service in the various versions the new\u00a0MP2Plus\u00a0is born. MP2Plus\u00a0is a Professional Digital Indicator with\u00a01\u00a0(standard)or\u00a02\u00a0(option)\u00a0inputs, suitable for receiving signals from strain gauge sensors, transmitters with voltage or current output, PT100, potentiometer, ENCODER and LVDT. Particularly suitable for both static and dynamic applications, for calibration and verification in metrology laboratories or industrial environments where it is necessary to make measurements of\u00a0WEIGHT, FORCE, PRESSURE, TORQUE, DISPLACEMENTS, ANGLE, SPEED\u00a0and\u00a0TEMPERATURE. To\u00a0FIT EVERY APPLICATION\u00a0the instrument can be configured and customized:\u00a0 the function keys F1, F2, F3 and F4 can be programmed for the function of interest such as: PEAK, HOLD, RELEASE, TX DATA DATALOG, DISCHARGE, ZOOM. Each input channels can be supplied in\u00a07\u00a0different configurations:   \u00b12mV\/V,\u00a0\u00b13mV\/V  4-20mA, 0-20mA  \u00b110V,\u00a0\u00b15V  PT100  ENCODER  POTENTIOMETER  LVDT  On request\u00a0FIELDBUS\u00a0communication selectable among :\u00a0DeviceNet,\u00a0CANopen,\u00a0EtherNet\/IP, PROFIBUS,\u00a0PROFINET\u00a0to be connected inside a standard PLC network. NEW\u00a0COUNTING\u00a0function","og_url":"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/","og_site_name":"AEP transducers","article_publisher":"https:\/\/www.facebook.com\/AEP-transducers-212611005540305","article_modified_time":"2025-11-03T14:42:20+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-mp2plus.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/","url":"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/","name":"MP2PLUS | AEP transducers","isPartOf":{"@id":"https:\/\/www.aep.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/#primaryimage"},"image":{"@id":"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/#primaryimage"},"thumbnailUrl":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-mp2plus.jpg","datePublished":"2019-12-20T08:14:54+00:00","dateModified":"2025-11-03T14:42:20+00:00","breadcrumb":{"@id":"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/#primaryimage","url":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-mp2plus.jpg","contentUrl":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-mp2plus.jpg","width":600,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/www.aep.it\/en\/product\/instruments\/mp2plus\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aep.it\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.aep.it\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"MP2PLUS"}]},{"@type":"WebSite","@id":"https:\/\/www.aep.it\/en\/#website","url":"https:\/\/www.aep.it\/en\/","name":"AEP transducers","description":"","publisher":{"@id":"https:\/\/www.aep.it\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aep.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.aep.it\/en\/#organization","name":"AEP Transducers","url":"https:\/\/www.aep.it\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png","contentUrl":"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png","width":2000,"height":284,"caption":"AEP Transducers"},"image":{"@id":"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/AEP-transducers-212611005540305"]}]}},"_links":{"self":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product\/3490","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/media\/3482"}],"wp:attachment":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/media?parent=3490"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product_brand?post=3490"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product_cat?post=3490"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product_tag?post=3490"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}