{"id":3658,"date":"2019-12-20T11:14:26","date_gmt":"2019-12-20T10:14:26","guid":{"rendered":"http:\/\/www.aep.it\/prodotto\/uncategorized\/ta2usb\/"},"modified":"2025-11-03T17:24:48","modified_gmt":"2025-11-03T16:24:48","slug":"ta2usb","status":"publish","type":"product","link":"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/","title":{"rendered":"TA2USB"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]Through the USB line is possible to make the configuration of the transmitter parameters including:<br \/>\nDigital Filter, ZERO<br \/>\nConversion Speed<br \/>\nOperating mode: Standard \/ Peak.<\/p>\n<p>Available versions are:<br \/>\nInput for load cells and dynamometers (standard)<br \/>\nInput for transducers with voltage output (\u00b110V). (option)<br \/>\nInput for transducers with current output (4-20mA) (option)<br \/>\nInput for PT100 for temperature measuring<\/p>\n<p>Frequency input for the measure of torsiometer rotational speed<\/p>\n<p>It is possible to have the instrument in a 4 channel version (option). In this case 2 channel are of strain gauge type while the other two can be selected as voltage, temperature or current input.<br \/>\nIn this version the acquisition time is reduced but the accuracy is the same.<br \/>\nThe connection to transducers is achieved through a standard SUB-D 9-pin female connector.<\/p>\n<p><strong>Complete with Software<\/strong>[\/vc_column_text][vc_separator][vc_column_text]<strong>ACCESSORIES<\/strong>[\/vc_column_text][vc_row_inner][vc_column_inner][vc_column_text]USB cable.<br \/>\nDB9 connector to connect the sensors to the transmitter.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The transmitter makes simple and economical the transmission of data coming from up to 2 load cells, transducers or potentiometers to a PC. TA2USB has a maximum resolution of \u00b150.000 divisions and transmits the data directly on-line USB 2.0. It is a very simple but complete instrument as it is self powered directly from the USB line and is ideal as acquisition system connected to a PC. The transmitter is controlled by a microcontroller that processes the data sampled by two 24bit ADC converters (one for each channels) at a frequency from 5 to 4800Hz. The instrument continuously transmits the value in divisions according to a protocol highly optimized and easy to implement and allows to get in real-time all the internal acquisition data. Accuracy\u00a0<strong>0,010%<\/strong> <img decoding=\"async\" class=\"alignnone size-medium wp-image-2921\" src=\"http:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/USB-300x100.jpg\" alt=\"\" width=\"300\" height=\"100\" srcset=\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/USB-300x100.jpg 300w, https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/USB.jpg 354w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-8975\" src=\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/label-eac-2.jpg\" alt=\"\" width=\"150\" height=\"70\" \/><\/p>\n","protected":false},"featured_media":3653,"template":"","meta":[],"product_brand":[],"product_cat":[89],"product_tag":[],"class_list":{"0":"post-3658","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-instruments","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple","12":"berocket_lgv_grid","13":"berocket_lgv_list_grid"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>TA2USB | AEP transducers<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TA2USB | AEP transducers\" \/>\n<meta property=\"og:description\" content=\"The transmitter makes simple and economical the transmission of data coming from up to 2 load cells, transducers or potentiometers to a PC. TA2USB has a maximum resolution of \u00b150.000 divisions and transmits the data directly on-line USB 2.0. It is a very simple but complete instrument as it is self powered directly from the USB line and is ideal as acquisition system connected to a PC. The transmitter is controlled by a microcontroller that processes the data sampled by two 24bit ADC converters (one for each channels) at a frequency from 5 to 4800Hz. The instrument continuously transmits the value in divisions according to a protocol highly optimized and easy to implement and allows to get in real-time all the internal acquisition data. Accuracy\u00a00,010%\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/\" \/>\n<meta property=\"og:site_name\" content=\"AEP transducers\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/AEP-transducers-212611005540305\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-03T16:24:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-ta2usb.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/\",\"url\":\"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/\",\"name\":\"TA2USB | AEP transducers\",\"isPartOf\":{\"@id\":\"https:\/\/www.aep.it\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-ta2usb.jpg\",\"datePublished\":\"2019-12-20T10:14:26+00:00\",\"dateModified\":\"2025-11-03T16:24:48+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/#primaryimage\",\"url\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-ta2usb.jpg\",\"contentUrl\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-ta2usb.jpg\",\"width\":600,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.aep.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.aep.it\/en\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"TA2USB\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.aep.it\/en\/#website\",\"url\":\"https:\/\/www.aep.it\/en\/\",\"name\":\"AEP transducers\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.aep.it\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.aep.it\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.aep.it\/en\/#organization\",\"name\":\"AEP Transducers\",\"url\":\"https:\/\/www.aep.it\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png\",\"contentUrl\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png\",\"width\":2000,\"height\":284,\"caption\":\"AEP Transducers\"},\"image\":{\"@id\":\"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/AEP-transducers-212611005540305\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"TA2USB | AEP transducers","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/","og_locale":"en_US","og_type":"article","og_title":"TA2USB | AEP transducers","og_description":"The transmitter makes simple and economical the transmission of data coming from up to 2 load cells, transducers or potentiometers to a PC. TA2USB has a maximum resolution of \u00b150.000 divisions and transmits the data directly on-line USB 2.0. It is a very simple but complete instrument as it is self powered directly from the USB line and is ideal as acquisition system connected to a PC. The transmitter is controlled by a microcontroller that processes the data sampled by two 24bit ADC converters (one for each channels) at a frequency from 5 to 4800Hz. The instrument continuously transmits the value in divisions according to a protocol highly optimized and easy to implement and allows to get in real-time all the internal acquisition data. Accuracy\u00a00,010%","og_url":"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/","og_site_name":"AEP transducers","article_publisher":"https:\/\/www.facebook.com\/AEP-transducers-212611005540305","article_modified_time":"2025-11-03T16:24:48+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-ta2usb.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/","url":"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/","name":"TA2USB | AEP transducers","isPartOf":{"@id":"https:\/\/www.aep.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/#primaryimage"},"image":{"@id":"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/#primaryimage"},"thumbnailUrl":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-ta2usb.jpg","datePublished":"2019-12-20T10:14:26+00:00","dateModified":"2025-11-03T16:24:48+00:00","breadcrumb":{"@id":"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/#primaryimage","url":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-ta2usb.jpg","contentUrl":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-ta2usb.jpg","width":600,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/www.aep.it\/en\/product\/instruments\/ta2usb\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aep.it\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.aep.it\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"TA2USB"}]},{"@type":"WebSite","@id":"https:\/\/www.aep.it\/en\/#website","url":"https:\/\/www.aep.it\/en\/","name":"AEP transducers","description":"","publisher":{"@id":"https:\/\/www.aep.it\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aep.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.aep.it\/en\/#organization","name":"AEP Transducers","url":"https:\/\/www.aep.it\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png","contentUrl":"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png","width":2000,"height":284,"caption":"AEP Transducers"},"image":{"@id":"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/AEP-transducers-212611005540305"]}]}},"_links":{"self":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product\/3658","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/media\/3653"}],"wp:attachment":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/media?parent=3658"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product_brand?post=3658"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product_cat?post=3658"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product_tag?post=3658"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}