{"id":3739,"date":"2019-12-20T12:12:54","date_gmt":"2019-12-20T11:12:54","guid":{"rendered":"http:\/\/www.aep.it\/prodotto\/uncategorized\/torquekal\/"},"modified":"2021-01-02T15:33:39","modified_gmt":"2021-01-02T14:33:39","slug":"torquekal","status":"publish","type":"product","link":"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/","title":{"rendered":"TORQUEKAL"},"content":{"rendered":"<p>[vc_row][vc_column][vc_column_text]<\/p>\n<p>Calibration consists of carrying out five measurements for each torque point calculated normally at 20%, 60% and 100% of the maximum torque value of the device being calibrated.<br \/>At the end of the test, the programme calculates, for each measurement point<br \/>a) the Average of the readings<br \/>b) the % Deviation<br \/>c) the Extended Uncertainty %.<\/p>\n<p>All the certificates are then printed and stored in a database to keep a record of the calibrations performed.<br \/>The programme manages a further database of Sample Instruments type BTR2 and MP10 connected to the PC via USB communication to guarantee measurement acquisition.<br \/>For each Sample Instrument, it is necessary to enter all the identification data, the ACCREDIA certificates or equivalent reference certificates and to enter the various uncertainties subdivided for the various torque points.<br \/>The programme automatically manages the expiry of the certificates, notifying the Operator if the certificate has expired.<\/p>\n<p>[\/vc_column_text][vc_separator][vc_column_text]<strong>ACCESSORIES<\/strong>[\/vc_column_text][vc_row_inner content_placement=&#8221;middle&#8221;][vc_column_inner][vc_column_text]See instrumentation and connection cables[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The programme is designed to perform calibration of torque tools using sample devices.<br \/>The calibration procedure is performed in accordance with the standard UNI <strong>EN ISO 6789-1<\/strong> and <strong>UNI EN ISO 6789-2: 2017<\/strong>.<br \/>The evaluation of the calibration uncertainty is carried out according to the requirements of the standard.<\/p>\n","protected":false},"featured_media":6724,"template":"","meta":[],"product_brand":[],"product_cat":[81],"product_tag":[],"class_list":{"0":"post-3739","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-software-applications","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple","12":"berocket_lgv_grid","13":"berocket_lgv_list_grid"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>TORQUEKAL | AEP transducers<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"TORQUEKAL | AEP transducers\" \/>\n<meta property=\"og:description\" content=\"The programme is designed to perform calibration of torque tools using sample devices.The calibration procedure is performed in accordance with the standard UNI EN ISO 6789-1 and UNI EN ISO 6789-2: 2017.The evaluation of the calibration uncertainty is carried out according to the requirements of the standard.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/\" \/>\n<meta property=\"og:site_name\" content=\"AEP transducers\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/AEP-transducers-212611005540305\" \/>\n<meta property=\"article:modified_time\" content=\"2021-01-02T14:33:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-torquekal-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/\",\"url\":\"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/\",\"name\":\"TORQUEKAL | AEP transducers\",\"isPartOf\":{\"@id\":\"https:\/\/www.aep.it\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-torquekal-1.jpg\",\"datePublished\":\"2019-12-20T11:12:54+00:00\",\"dateModified\":\"2021-01-02T14:33:39+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/#primaryimage\",\"url\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-torquekal-1.jpg\",\"contentUrl\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-torquekal-1.jpg\",\"width\":600,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.aep.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.aep.it\/en\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"TORQUEKAL\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.aep.it\/en\/#website\",\"url\":\"https:\/\/www.aep.it\/en\/\",\"name\":\"AEP transducers\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.aep.it\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.aep.it\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.aep.it\/en\/#organization\",\"name\":\"AEP Transducers\",\"url\":\"https:\/\/www.aep.it\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png\",\"contentUrl\":\"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png\",\"width\":2000,\"height\":284,\"caption\":\"AEP Transducers\"},\"image\":{\"@id\":\"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/AEP-transducers-212611005540305\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"TORQUEKAL | AEP transducers","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/","og_locale":"en_US","og_type":"article","og_title":"TORQUEKAL | AEP transducers","og_description":"The programme is designed to perform calibration of torque tools using sample devices.The calibration procedure is performed in accordance with the standard UNI EN ISO 6789-1 and UNI EN ISO 6789-2: 2017.The evaluation of the calibration uncertainty is carried out according to the requirements of the standard.","og_url":"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/","og_site_name":"AEP transducers","article_publisher":"https:\/\/www.facebook.com\/AEP-transducers-212611005540305","article_modified_time":"2021-01-02T14:33:39+00:00","og_image":[{"width":600,"height":600,"url":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-torquekal-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/","url":"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/","name":"TORQUEKAL | AEP transducers","isPartOf":{"@id":"https:\/\/www.aep.it\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/#primaryimage"},"image":{"@id":"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/#primaryimage"},"thumbnailUrl":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-torquekal-1.jpg","datePublished":"2019-12-20T11:12:54+00:00","dateModified":"2021-01-02T14:33:39+00:00","breadcrumb":{"@id":"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/#primaryimage","url":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-torquekal-1.jpg","contentUrl":"https:\/\/www.aep.it\/wp-content\/uploads\/2019\/12\/aep-transducers-torquekal-1.jpg","width":600,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/www.aep.it\/en\/product\/software-applications\/torquekal\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aep.it\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.aep.it\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"TORQUEKAL"}]},{"@type":"WebSite","@id":"https:\/\/www.aep.it\/en\/#website","url":"https:\/\/www.aep.it\/en\/","name":"AEP transducers","description":"","publisher":{"@id":"https:\/\/www.aep.it\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aep.it\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.aep.it\/en\/#organization","name":"AEP Transducers","url":"https:\/\/www.aep.it\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png","contentUrl":"https:\/\/www.aep.it\/wp-content\/uploads\/2020\/03\/logo-vettoriale-def.png","width":2000,"height":284,"caption":"AEP Transducers"},"image":{"@id":"https:\/\/www.aep.it\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/AEP-transducers-212611005540305"]}]}},"_links":{"self":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product\/3739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/media\/6724"}],"wp:attachment":[{"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/media?parent=3739"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product_brand?post=3739"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product_cat?post=3739"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.aep.it\/en\/wp-json\/wp\/v2\/product_tag?post=3739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}